CME Analysis Information (for CME activity ID: 2025-06-02T13:25:00-CME-001)
Catalog: M2M_CATALOG
Data Level: 0 (0=real-time, 1=real-time and checked by supervising forecaster, 2=retrospective science level data analysis)
Use as primary measurement: true
Measurement Technique:
SWPC_CAT
Detecting Instruments:
SOHO: LASCO/C3
STEREO A: SECCHI/COR2
Image Type:
running difference
Speed (km/s):
402.0
Speed measured at height (Rs):
17.0
Type: S
Direction (LON/LAT in HEEQ):
6.0/
73.0
Half Angular Width (degree): 28.0
Minor Half-width (degree): None Entered
Tilt (degree): None Entered
Time@21.5: 2025-06-03T04:28Z
Info/Session URL: None Entered
Note: Best fit measurement using multiple frames of SOHO LASCO C3 and two usable frames of STEREO A COR2. Analysis of this CME was affected by a data gap in STEREO A COR2 which lasted from 2025-06-02T23:53Z to 2025-06-03T00:53Z, resulting in there being two usable frames before the tracked feature exited the STEREO A COR2 field of view.
Measurement Feature Code(s):
LE: Leading Edge
General Keyword(s):
Version 1 submitted on 2025-06-03T18:56Z by Hannah Hermann