CME Analysis Information (for CME activity ID: 2025-01-28T08:24:00-CME-001)
Catalog: M2M_CATALOG
Data Level: 0 (0=real-time, 1=real-time and checked by supervising forecaster, 2=retrospective science level data analysis)
Use as primary measurement: true
Measurement Technique:
SWPC_CAT
Detecting Instruments:
SOHO: LASCO/C2
SOHO: LASCO/C3
STEREO A: SECCHI/COR2
Image Type:
running difference
Speed (km/s):
459.0
Speed measured at height (Rs):
10.0
Type: S
Direction (LON/LAT in HEEQ):
109.0/
-27.0
Half Angular Width (degree): 36.0
Minor Half-width (degree): None Entered
Tilt (degree): None Entered
Time@21.5: 2025-01-28T16:42Z
Info/Session URL: None Entered
Note: Measurement using location of source observed in UV imagery and best fit between SOHO LASCO C2/C3 and STEREO A COR2. Leading edge is very faint, especially in STEREO A COR2 imagery.
Measurement Feature Code(s):
LE: Leading Edge
General Keyword(s):
Version 1 submitted on 2025-01-28T20:03Z by Hannah Hermann
No Notification has been sent for this activity yet.
|