CME Analysis Information (for CME activity ID: 2023-06-17T10:48:00-CME-001)
Measurement Creation Time: 2023-06-17T15:08Z
Catalog: M2M_CATALOG
Data Level: 0 (0=real-time, 1=real-time and checked by supervising forecaster, 2=retrospective science level data analysis)
Use as primary measurement: true
Measurement Technique:
SWPC_CAT
Detecting Instruments:
SOHO: LASCO/C3
STEREO A: SECCHI/COR2
Image Type:
running difference
Speed (km/s):
573.0
Speed measured at height (Rs): None Entered
Type: C
Direction (LON/LAT in HEEQ):
-95.0/
-42.0
Half Angular Width (degree): 37.0
Minor Half-width (degree): None Entered
Tilt (degree): None Entered
Time@21.5: 2023-06-17T17:18Z
Info/Session URL: None Entered
Note: The CME appears to have an asymmetrical front which made it tricky to get a good fit of the leading edge. The main bulk portion is captured in this measurement. The more northern, fainter portion of the CME front was excluded from this measurement. The speed appears to decrease the further out in the field of view the measurements are taken, also the CME appears to have deflected towards the south as the filament expanded out in the field of view.
Measurement Feature Code(s):
LE: Leading Edge
General Keyword(s):
Version 1 submitted on 2023-06-17T15:08Z by Carina Alden
No Notification has been sent for this activity yet.
|