DONKI: Menu Page
Go to:
|
DONKI: View SW Activity
Coronal Mass Ejection
Catalog: M2M_CATALOG
Start Time: 2025-03-11T05:23Z ( STEREO A: SECCHI/COR2 )
All Detecting Spacecrafts:
STEREO A: SECCHI/COR2
SOHO: LASCO/C2
SOHO: LASCO/C3
Activity ID: 2025-03-11T05:23:00-CME-001 (version 2)
Note Keyword:
Faint: Faint event; may affect type assignment
Source Signature Keyword:
OFL: Moving/Opening field lines
BR: Brightening
Morphology Keyword:
L: Loop
Note: Faint and relatively narrow CME to the southwest in STEREO A COR2 and SOHO LASCO C2 and C3 imagery. The leading edge appears slightly brighter in STEREO A COR2 than in SOHO LASCO. The source is opening field lines seen starting at 2025-03-11T03:35Z located on or just beyond the W limb as seen in STEREO A EUVI 195 (W120-130 from SDO AIA perspective) and spanning approximately N00 to S10 in latitude, although the eruption likely extends to farther beyond the limb. Field line movement and the disappearance of a small loop of material can be seen from the same location in STEREO A EUVI 304 imagery between the 2025-03-11T03:45Z and 2025-03-11T04:45Z frames.
Submitted on 2025-03-11T16:51Z by Hannah
Hermann
A Notification with ID
20250311-AL-001 was sent on 2025-03-11T17:00Z
|
The List of CME Analysis already entered: |
Event Type |
Catalog |
Measurement TypeCME measurement type: Leading Edge (LE), Shock Front (SH), Right Hand Boundary (RHB), Left Hand Boundary (LHB), Black/White Boundary (BW), Prominence Core (COR), Disconnection Front (DIS), Trailing Edge (TE). |
Prime?"primary flag" which is either True or False. If there are multiple CME analysis entries for a single CME, this flag would indicate which analysis is considered most accurate per measurement type. This is a helpful flag if you would like to download only one most accurate CME analysis per CME per Measurement Type |
Technique |
Long |
Lat |
Speed |
Type |
Half Width |
Time 21.5 |
Note |
WSA-ENLIL+Cone Result(s) |
Submitted By |
CME Analysis
|
M2M_CATALOG |
LE
|
true |
SWPC_CAT |
130.0 |
-9.0 |
1141.0 |
O |
18.0 |
2025-03-11T08:17Z |
Measurement using source location seen in UV imagery and best fit between a few frames of SOHO LASCO C3 and STEREO A COR2 running difference imagery. The leading edge is very faint in both coronagraphs and becomes too diffuse to reliably track about halfway through the SOHO LASCO C3 field of view. |
1: Result 1 (2.0 AU)
Juice = 2025-03-13T18:00Z
|
Hannah Hermann on 2025-03-11T16:43Z |
|
All directly linked activities: |
No Linked Activity Found. |
|
Comments by users: |
0 comment received. |
|