DONKI: Menu Page
Go to:
|
DONKI: View SW Activity
Coronal Mass Ejection
Catalog: M2M_CATALOG
Start Time: 2024-01-30T00:24Z ( SOHO: LASCO/C2 )
All Detecting Spacecrafts:
SOHO: LASCO/C2
SOHO: LASCO/C3
STEREO A: SECCHI/COR2
Activity ID: 2024-01-30T00:24:00-CME-001 (version 2)
Source Location: N27W80
Active Region Number: 13559
Note Keyword:
Faint: Faint event; may affect type assignment
GAP: Data gap
Source Signature Keyword:
FLR: Flare
OFL: Moving/Opening field lines
BR: Brightening
Morphology Keyword:
US: Unknown and Shock Candidate
Note: Faint CME visible in the NW of SOHO LASCO C2/C3 and STEREO A COR2. The start of this CME is not visible in STEREO A COR2 due to a data gap from 2024-01-29T13:38Z to 2024-01-30T01:53Z. The source is an eruption just north of AR 3559, approx. N25W80, seen starting at 2024-01-30T00:29Z in SDO AIA 193 as brightening and opening field lines. This may be associated with a C1.9 flare peaking at 2024-01-30T00:16Z from AR 3559. Opening field lines are also seen in SDO AIA 171. The eruption is not visible in STEREO A EUV imagery due to the data gap.
Submitted on 2024-01-30T14:01Z by Mary
Aronne
A Notification with ID
20240130-AL-002 was sent on 2024-01-30T20:52Z
|
The List of CME Analysis already entered: |
Event Type |
Catalog |
Measurement TypeCME measurement type: Leading Edge (LE), Shock Front (SH), Right Hand Boundary (RHB), Left Hand Boundary (LHB), Black/White Boundary (BW), Prominence Core (COR), Disconnection Front (DIS), Trailing Edge (TE). |
Prime?"primary flag" which is either True or False. If there are multiple CME analysis entries for a single CME, this flag would indicate which analysis is considered most accurate per measurement type. This is a helpful flag if you would like to download only one most accurate CME analysis per CME per Measurement Type |
Technique |
Long |
Lat |
Speed |
Type |
Half Width |
Time 21.5 |
Note |
WSA-ENLIL+Cone Result(s) |
Submitted By |
CME Analysis
|
M2M_CATALOG |
LE
|
true |
SWPC_CAT |
80.0 |
26.0 |
563.0 |
C |
18.0 |
2024-01-30T06:23Z |
Limited STEREO A COR2 frames were available for this measurement due to the faintness of the leading edge. There may be a fainter feature, possibly a shock, ahead of the bulk of this CME, which was not measurable due to it's faintness. |
1: Result 1 (2.0 AU)
OSIRIS-APEX = 2024-02-01T14:00Z
2: Result 2 (5.5 AU)
OSIRIS-APEX = 2024-02-01T14:00Z
|
Mary Aronne on 2024-01-30T13:37Z |
|
All directly linked activities: |
|
|
Comments by users: |
0 comment received. |
|